Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 450
Filtrar
1.
ADMET DMPK ; 12(1): 167-176, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38560714

RESUMO

Background and purpose: Doxazosin mesylate (DOX) is an antihypertensive drug that possesses poor water solubility and, hence, poor release properties. Both nanosuspensions and self-nanoemulsifying drug delivery systems (SNEDDS) are becoming nanotechnology techniques for the enhancement of water solubility of different drugs. Experimental approach: The study's goal was to identify the best drug delivery system able to enhance the release and antihypertensive effect of DOX by comparing the physical characteristics such as particle size, zeta potential, entrapment efficiency, release rate, and main arterial blood pressure of DOX-loaded nanosuspensions and SNEDDS in liquid and solid form. Key results: DOX nanosuspension preparation had a particle size of 385±13 nm, poly-dispersity index of 0.049±3, zeta potential of 50 ± 4 mV and drug release after 20 min (91±0.43 %). Liquid SNEDDS had a droplet size of 224±15 nm, poly-dispersity index of (0.470±0.01), zeta potential of -5±0.10 mV and DR20min of 93±4 %. Solid SEDDS showed particle size of 79±14 nm, poly-dispersity index of 1±0.00, a zeta potential of -18 ±0.26 mv and DR20min of 100 ±2.72 %. Conclusion: Finally, in terms of the mean arterial blood pressure lowering, solid SNEDDS performed better effect than both liquid SNEDDS and nanosuspension (P >0.05).

5.
medRxiv ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38496617

RESUMO

Background and Objective: Detection of the dicrotic notch (DN) within a cardiac cycle is essential for assessment of cardiac output, calculation of pulse wave velocity, estimation of left ventricular ejection time, and supporting feature-based machine learning models for noninvasive blood pressure estimation, and hypotension, or hypertension prediction. In this study, we present a new algorithm based on the iterative envelope mean (IEM) method to detect automatically the DN in arterial blood pressure (ABP) and photoplethysmography (PPG) waveforms. Methods: The algorithm was evaluated on both ABP and PPG waveforms from a large perioperative dataset (MLORD dataset) comprising 17,327 patients. The analysis involved a total of 1,171,288 cardiac cycles for ABP waveforms and 3,424,975 cardiac cycles for PPG waveforms. To evaluate the algorithm's performance, the systolic phase duration (SPD) was employed, which represents the duration from the onset of the systolic phase to the DN in the cardiac cycle. Correlation plots and regression analysis were used to compare the algorithm with an established DN detection technique (second derivative). The marking of the DN temporal location was carried out by an experienced researcher using the help of the 'find_peaks' function from the scipy PYTHON package, serving as a reference for the evaluation. The marking was visually validated by both an engineer and an anesthesiologist. The robustness of the algorithm was evaluated as the DN was made less visually distinct across signal-to-noise ratios (SNRs) ranging from -30 dB to -5 dB in both ABP and PPG waveforms. Results: The correlation between SPD estimated by the algorithm and that marked by the researcher is strong for both ABP (R2(87343) =.99, p<.001) and PPG (R2(86764) =.98, p<.001) waveforms. The algorithm had a lower mean error of dicrotic notch detection (s): 0.0047 (0.0029) for ABP waveforms and 0.0046 (0.0029) for PPG waveforms, compared to 0.0693 (0.0770) for ABP and 0.0968 (0.0909) for PPG waveforms for the established 2nd derivative method. The algorithm has high accuracy of DN detection for SNR of >= -9 dB for ABP waveforms and >= -12 dB for PPG waveforms indicating robust performance in detecting the DN when it is less visibly distinct. Conclusion: Our proposed IEM- based algorithm can detect DN in both ABP and PPG waveforms with low computational cost, even in cases where it is not distinctly defined within a cardiac cycle of the waveform ('DN-less signals'). The algorithm can potentially serve as a valuable, fast, and reliable tool for extracting features from ABP and PPG waveforms. It can be especially beneficial in medical applications where DN-based features, such as SPD, diastolic phase duration, and DN amplitude, play a significant role.

6.
Scand J Trauma Resusc Emerg Med ; 32(1): 20, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475832

RESUMO

BACKGROUND: Accurate haemodynamic monitoring in the prehospital setting is essential. Non-invasive blood pressure measurement is susceptible to vibration and motion artefact, especially at extremes of hypotension and hypertension: invasive arterial blood pressure (IABP) monitoring is a potential solution. This study describes the largest series to date of cases of IABP monitoring being initiated prehospital. METHODS: This retrospective observational study was conducted at East Anglian Air Ambulance (EAAA), a UK helicopter emergency medical service (HEMS). It included all patients attended by EAAA who underwent arterial catheterisation and initiation of IABP monitoring between 1st February 2015 and 20th April 2023. The following data were retrieved for all patients: sex; age; aetiology (medical cardiac arrest, other medical emergency, trauma); site of arterial cannulation; operator role (doctor/paramedic); time of insertion and, where applicable, times of pre-hospital emergency anaesthesia, and return of spontaneous circulation following cardiac arrest. Descriptive analyses were performed to characterise the sample. RESULTS: 13,556 patients were attended: IABP monitoring was initiated in 1083 (8.0%) cases, with a median age 59 years, of which 70.8% were male. 546 cases were of medical cardiac arrest: in 22.4% of these IABP monitoring was initiated during cardiopulmonary resuscitation. 322 were trauma cases, and the remaining 215 were medical emergencies. The patients were critically unwell: 981 required intubation, of which 789 underwent prehospital emergency anaesthesia; 609 received vasoactive medication. In 424 cases IABP monitoring was instituted en route to hospital. CONCLUSION: This study describes over 1000 cases of prehospital arterial catheterisation and IABP monitoring in a UK HEMS system and has demonstrated feasibility at scale. The high-fidelity of invasive arterial blood pressure monitoring with the additional benefit of arterial blood gas analysis presents an attractive translation of in-hospital critical care to the prehospital setting.


Assuntos
Resgate Aéreo , Serviços Médicos de Emergência , Parada Cardíaca , Monitorização Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Pressão Sanguínea , Pressão Arterial , Estudos Retrospectivos , Estado Terminal , Aeronaves , Reino Unido
7.
J Cereb Blood Flow Metab ; : 271678X231224504, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466898

RESUMO

Driven and spontaneous methods have been used to quantify the cerebral pressure-flow relationship via transfer function analysis (TFA). Commonly, TFA derived estimates are assessed using band averages within the very-low (0.02-0.07 Hz) and low (0.07-0.20 Hz) frequency during spontaneous oscillations but are quantified at frequencies of interest where blood pressure oscillations are driven (e.g., 0.05 and/or 0.10 Hz). Driven estimates more closely resemble the autoregulatory challenges individuals experience on a daily basis, while also eliciting higher levels of reliability. While driven estimates with point-estimates are not feasible for all clinical populations, these approaches increase the ability to understand pathophysiological changes.

8.
Med Eng Phys ; 123: 104085, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38365338

RESUMO

Extreme bradycardia, extreme tachycardia, ventricular flutter fib, and ventricular tachycardia are four malignant arrhythmias (MAs) that lead to sudden cardiac death. It is very important to detect them in daily life. The arterial blood pressure (ABP) signal contains abundant pathological information about four MAs and is easy to be recorded under domestic conditions. Thus, a synthesis-by-analysis (SA) modeling method for ABP signal was proposed to detect the four MAs in this study. The average models of MAs and healthy subjects were obtained by SA modeling, and the change of each ABP wave was quantitively described by twelve parameters of wave models. Then, the probabilistic neural network (PNN) and random forest (RF) are trained to detect the MAs. The experimental data were employed from Fantasia and the 2015 PhysioNet/CinC Challenge databases. The SA modeling results show that some pathological and physiological changes could be extracted from the average models. The two-sample ks-test results between different groups are markedly different (h = 1, p < 0.05). The detection results show that the performances of PPN classifiers are less than that of RF. The kappa coefficients (KC) for the RF classifiers are 97.167 ± 1.46 %, 97.888 ± 0.808 %, 99.895 ± 0.545 %, 98.575 ± 1.683 % and 92.241 ± 1.517 %, respectively. The mean KC is 97.083 ± 0.67 %. Compared to the performance of some existing studies, the proposed method has better performance and is potential to diagnose MAs in m-health.


Assuntos
Pressão Arterial , Eletrocardiografia , Humanos , Arritmias Cardíacas/diagnóstico , Redes Neurais de Computação , Pressão Sanguínea
9.
Heliyon ; 10(4): e25794, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38375271

RESUMO

Purpose: To explore intraocular pressure (IOP) and its associated parameters in an aged population. Methods: The epidemiologic Ural Very Old Study (UVOS) conducted in Bashkortostan/Russia included 1526 participants with an age of ≥85 years. Besides a whole series of ocular and systemic examinations, IOP was determined applying non-contact tonometry. Body mass index, diastolic blood pressure and age were the factors used to estimate the cerebrospinal fluid pressure (CSFP). Results: The study consisted of 904 participants (age: 88.6 ± 2.7 years) with available IOP readings and without anti-glaucomatous therapy. Mean IOP was 14.5 ± 5.1 mmHg (median: 14 mm Hg; Q1:11; Q3:16; 95%CI:8,25) and 14.8 ± 4.6 mmHg (median: 14 mm Hg; Q1:12; Q3:17; 95%CI:8,28) in the right and left eyes, respectively. Higher IOP correlated (multivariable analysis; correlation coefficient r2:0.32) with female sex (P < 0.001), more sedentary lifestyle (P = 0.006), higher estimated CSFP (P < 0.001), higher total protein serum concentration (P < 0.001), stronger hand grip force (P = 0.01), thicker central cornea (P < 0.001), longer axial length (P = 0.01), absence of previous cataract surgery (P = 0.001), higher degree of pseudoexfoliation (P = 0.02, and thinner peripapillary retinal nerve fiber layer thickness (P = 0.004). Using this that model, IOP reading enlarged by 0.22 mmHg (95% CI: 0.09, 0.35) for each increase in estimated CSFP by 1 mm Hg, by 0.03 mm Hg (95% CI: 0.02,0.05) for each thickening in central corneal thickness by 1 µm, by 0.56 mm Hg (95%CI: 0.13,1.00) for each axial elongation by 1 mm, and by 0.40 mmHg (95% CI: 0.06,0.74) for each increase in the degree of pseudoexfoliation, and it decreased by 0.40 mmHg (95% CI: 0.06,0.74) by cataract surgery. Conclusions: In this study population aged 85+years, IOP readings showed similar relationships as in younger study populations, including positive associations with higher estimated CSFP and longer axial length and a negative association with cataract surgery.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38220129

RESUMO

The baroreflex involves cardiovascular homeostatic mechanisms that buffer the system against acute deviations in arterial blood pressure. It is comprised of the cardiac limb which involves adjustments in heart rate and the peripheral limb which involves adjustments in vascular resistance. This negative feedback loop mechanism has been investigated in numerous species of adult vertebrates, however our understanding of the maturation and functional importance of the reflex in developing animals remains poorly understood. In egglaying species, our knowledge of this mechanism is limited to the domestic chicken embryo and the embryonic alligator. While each of these species possess a cardiac baroreflex prior to hatching, they differ in the timing when it becomes functional, with the embryonic chicken possessing the reflex at 90% of incubation, while the alligator possesses the reflex at 70% of incubation. In an effort to determine if bird species might share similar patterns of active baroreflex function, we studied embryonic emus (Dromiceius novaehollandiae). However, we hypothesized that emus would possess a pattern of baroreflex function similar to that of the American alligator given the emu embryo possesses functional vagal tone at 70% of incubation, possibly indicating a more mature collection of cardiovascular control mechanism than those found in embryonic chickens. Our findings illustrate that emu embryos possess a hypotensive baroreflex at 90% of incubation. Therefore, our data fail to support our original hypothesis. While only two species of birds have been studied in this context, it could indicate that baroreflex function is not essential for cardiovascular homeostasis in birds for the majority of in ovo development.


Assuntos
Sistema Cardiovascular , Dromaiidae , Embrião de Galinha , Animais , Barorreflexo/fisiologia , Galinhas , Pressão Arterial , Frequência Cardíaca/fisiologia , Pressão Sanguínea/fisiologia
13.
J Pers Med ; 14(1)2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38248770

RESUMO

Beat-to-beat estimates of cardiac output from the direct measure of peripheral arterial blood pressure rely on the assumption that changes in the waveform morphology are related to changes in blood flow and vasomotor tone. However, in septic shock patients, profound changes in vascular tone occur that are not uniform across the entire arterial bed. In such cases, cardiac output estimates might be inaccurate, leading to unreliable evaluation of fluid responsiveness. Pulse wave velocity is the gold-standard method for assessing different arterial biomechanical properties. Such methods might be able to guide, personalize and optimize the management of septic patients.

14.
Vet Anaesth Analg ; 51(1): 1-9, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37852861

RESUMO

OBJECTIVE: To evaluate the agreement between noninvasive arterial blood pressure (NIBP) measured from the tongue and thoracic limb with invasive blood pressure (IBP), and to compare NIBP measured from the tongue and thoracic limb in anaesthetized horses. STUDY DESIGN: Prospective clinical study. ANIMALS: A group of eight client-owned healthy horses anaesthetized for scheduled procedures, American Society of Anesthesiologists classification I-II, weighing (mean ± standard deviation) 498 ± 91 kg and aged 7.8 ± 6.75 years. METHODS: Animals were premedicated with intravenous (IV) romifidine (0.04-0.08 mg kg-1) and methadone (0.1 mg kg-1). General anaesthesia was induced IV with ketamine (2.5 mg kg-1) and midazolam (0.05 mg kg-1) and maintained with isoflurane. The facial artery was catheterized for IBP measurements. Systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures were recorded from the NIBPtongue, NIBPlimb and IBP every 20 minutes during the procedure. Agreement between NIBP and IBP was evaluated based on the American College of Veterinary Internal Medicine criteria and American Association for Medical Instrumentation criteria using the Bland-Altman method. RESULTS: The mean bias and precision between IBP and NIBP measured from the tongue met the standards for all pressure ranges (< 10 mmHg and < 15 mmHg, respectively). NIBP measurements from the tongue and thoracic limb tended to underestimate IBP measurements. During hypotension, MAPtongue and DAPtongue overestimated IBP, but both precision and accuracy met the criteria. The overall accuracy and precision of NIBPlimb was poorer than NIBPtongue. The percentage of NIBPtongue that differed from IBP by < 10 mmHg was higher than that recorded with NIBPlimb for SAP (46% versus 25%), MAP (77% versus 28%) and DAP (79% versus 19%). CONCLUSIONS AND CLINICAL RELEVANCE: The tongue is a clinically suitable alternative for assessing arterial blood pressure compared with the thoracic limb and can reliably detect hypotension in healthy anaesthetized horses.


Assuntos
Doenças dos Cavalos , Hipotensão , Animais , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/veterinária , Monitores de Pressão Arterial/veterinária , Cavalos , Hipotensão/veterinária , Estudos Prospectivos , Língua
15.
Resuscitation ; 194: 110007, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37863419

RESUMO

BACKGROUND: Out-of-hospital cardiac arrest (OHCA) survivors remaining comatose are often circulatory unstable with high mortality in the first days following resuscitation. Elevated lactate will reflect the severity and duration of hypoperfusion in cardiac arrest. Further, the severity of hypoperfusion could modify the effect on survival of different mean arterial blood pressure (MAP) targets. METHODS: In this sub-study of the BOX trial, adult successfully resuscitated comatose OHCA patients (n = 789) with a presumed cardiac cause were randomized to a MAP target of 63 mmHg vs. 77 mmHg. Patients were arbitrarily grouped in low-lactate: <25% of sample, medium-lactate: 25%-75%, and high >75 percentile according to blood lactate levels at hospital arrival as a surrogate of the severity of hypoperfusion. Invasive hemodynamic evaluations were performed using an arterial catheter and pulmonary artery catheter (PAC), and data from admission to 48 hours (h) were recorded. Logistic regression analysis evaluated whether lactate levels (as continuous and categorical) modify the effect of MAP targets on mortality at 365 days. RESULTS: The three lactate groups had initial lactate levels of low-lactate: <2.9 mmol/L, medium-lactate: 2.9-7.9 mmol/L, and high-lactate > 7.9 mmol/L. All patients were randomized to a 63 mmHg or 77 mmHg MAP target. The proportion of patients in the high-MAP target group was 100/201 (50%), 178/388 (46%), and 114/197 (58%) for low, medium, and high-lactate groups respectively. At admission, the high-lactate groups had a lower MAP compared to the medium-lactate (2.6 mmHg (95% CI: 0.1-5.0 mmHg, p = 0.02), and the low-lactate group, (3.6 mmHg (95% CI: 0.8-6.5 mmHg, p < 0.01). Accordingly, the vasoactive inotropic score was 79% (95%CI: 42%-124%%) higher with increasing initial lactate level (High-lactate vs. low-lactate) with the largest difference at 6 hours (110.6% (95%CI: 54.4%-187.2%) higher in high-lactate patients). No difference in the cardiac index or systemic vascular resistance was observed between lactate groups. The initial lactate level (continuous) modified the effect of the two MAP targets (p = 0.04). In the highest lactate group, the mortality was 100/197 (51%), and with an odds ratio (OR): 1.7 (95%CI: 0.9-3.0) if randomized to MAP 77 mmHg compared to MAP 63 mmHg. In the lowest lactate group, the mortality was 35/201(17%) and similar if randomized to a MAP target of 77 mmHg (OR: 1.1 (95% CI: 0.5-2.3)). CONCLUSION: Comatose OHCA patients with high initial lactate levels required more vasoactive drugs on the first two days of ICU admission to meet the blood pressure target and had a poorer prognosis. No indication that aiming for a higher MAP target is beneficial in patients with an initial high lactate level was found, however, given the post-hoc nature of this study, these results should be considered hypothesis-generating.


Assuntos
Parada Cardíaca Extra-Hospitalar , Adulto , Humanos , Pressão Sanguínea , Coma , Hemodinâmica , Ácido Láctico
16.
Can J Anaesth ; 71(1): 107-117, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37932650

RESUMO

PURPOSE: Cerebral autoregulation (CA) is a mechanism that acts to maintain consistent cerebral perfusion across a range of blood pressures, and impaired CA is associated with delirium. Individualized CA-derived blood pressure targets are poorly characterized in critically ill patients and the association with intensive care unit (ICU) delirium is unknown. Our objectives were to characterize optimal mean arterial pressure (MAPopt) ranges in critically ill adults without brain injury and determine whether deviations from these targets contribute to ICU delirium. METHODS: We performed a retrospective cohort analysis of patients with shock of any etiology and/or respiratory failure requiring invasive mechanical ventilation, without a neurologic admitting diagnosis. Patients were screened daily for delirium. Cerebral oximetry and mean arterial pressure data were captured for the first 24 hr from enrolment. RESULTS: Forty-two patients with invasive blood pressure monitoring data were analyzed. Optimal mean arterial pressure targets ranged from 55 to 100 mm Hg. Optimal mean arterial pressure values were not significantly different based on history of hypertension or delirium status, and delirium was not associated with deviations from MAPopt. Nevertheless, the majority (69%) of blood pressure targets exceeded the current 65 mm Hg Surviving Sepsis guidelines. CONCLUSION: We observed that MAPopt targets across patients were highly variable, but did not observe an association with the incidence of delirium. Studies designed to evaluate the impact on neurologic outcomes are needed to understand the association with individualized mean arterial pressure targets in the ICU. STUDY REGISTRATION: ClinicalTrials.gov (NCT02344043); first submitted 22 January 2015.


RéSUMé: OBJECTIF: L'autorégulation cérébrale (AC) est un mécanisme qui agit pour maintenir une perfusion cérébrale constante pour une gamme de tensions artérielles, et une altération de l'AC est associée au delirium. Les cibles de tension artérielle individualisées dérivées de l'AC sont mal caractérisées chez les patient·es gravement malades et l'association avec le delirium à l'unité de soins intensifs (USI) est inconnue. Nos objectifs étaient de caractériser la tension artérielle moyenne optimale (TAMopt) chez les adultes gravement malades sans lésion cérébrale et de déterminer si les écarts par rapport à ces cibles contribuaient au delirium à l'USI. MéTHODE: Nous avons réalisé une analyse de cohorte rétrospective de patient·es présentant un choc de toute étiologie et/ou une insuffisance respiratoire nécessitant une ventilation mécanique invasive, et n'ayant pas reçu de diagnostic d'atteinte neurologique à l'admission. Les patients ont été dépistés quotidiennement pour le delirium. Les données d'oxymétrie cérébrale et de tension artérielle moyenne ont été saisies pendant les 24 premières heures suivant le recrutement. RéSULTATS: Quarante-deux patient·es pour qui des données de monitorage invasif de la tension artérielle étaient disponibles ont été analysé·es. Les cibles optimales de tension artérielle moyenne variaient de 55 à 100 mm Hg. Les valeurs optimales de tension artérielle moyenne n'étaient pas significativement différentes en fonction des antécédents d'hypertension ou de delirium, et le delirium n'était pas associé à des écarts par rapport à la TAMopt. Néanmoins, la majorité (69 %) des cibles de tension artérielle dépassaient celle de 65 mm Hg préconisée par les lignes directrices Surviving Sepsis. CONCLUSION: Nous avons observé que les cibles de TAMopt étaient très variables chez les patient·es, mais nous n'avons pas observé d'association avec l'incidence de delirium. Des études conçues pour évaluer l'impact sur les issues neurologiques sont nécessaires pour comprendre l'association avec les cibles de tension artérielle moyenne individualisées à l'USI. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT02344043); soumis pour la première fois le 22 janvier 2015.


Assuntos
Lesões Encefálicas , Delírio , Adulto , Humanos , Pressão Arterial/fisiologia , Estudos Retrospectivos , Circulação Cerebrovascular/fisiologia , Estado Terminal , Oximetria , Estudos Prospectivos , Estudos de Coortes , Lesões Encefálicas/complicações , Homeostase/fisiologia , Delírio/epidemiologia , Delírio/etiologia
17.
Ultrasound Obstet Gynecol ; 63(2): 230-236, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37616530

RESUMO

OBJECTIVE: To validate and extend a model incorporating maternal ophthalmic artery Doppler at 35-37 weeks' gestation in the prediction of subsequent development of pre-eclampsia (PE). METHODS: This was a prospective validation study of screening for PE (defined according to the 2019 American College of Obstetricians and Gynecologists criteria) by maternal ophthalmic artery peak systolic velocity (PSV) ratio in 6746 singleton pregnancies undergoing routine care at 35 + 0 to 36 + 6 weeks' gestation (validation dataset). Additionally, the data from the validation dataset were combined with those of 2287 pregnancies that were previously used for development of the model (training dataset), and the combined data were used to update the original model parameters. The competing-risks model was used to estimate the individual patient-specific risk of delivery with PE at any time and within 3 weeks from assessment by a combination of maternal demographic characteristics and medical history with PSV ratio alone and in combination with the established PE biomarkers of mean arterial pressure (MAP), uterine artery pulsatility index (UtA-PI), serum placental growth factor (PlGF) and serum soluble fms-like tyrosine kinase-1 (sFlt-1). We evaluated the predictive performance of the model by examining, first, the ability to discriminate between the PE and non-PE groups using the area under the receiver-operating-characteristics curve and the detection rate (DR) at fixed screen-positive (SPR) and false-positive rates of 10% and, second, calibration by measuring the calibration slope and calibration-in-the-large. McNemar's test was used to compare the performance of screening by a biophysical test (maternal factors, MAP, UtA-PI and PSV ratio) vs a biochemical test (maternal factors, PlGF and sFlt-1), low PlGF concentration (< 10th percentile) or high sFlt-1/PlGF concentration ratio (> 90th percentile). RESULTS: In the validation dataset, the performance of screening by maternal factors and PSV ratio for delivery with PE within 3 weeks and at any time after assessment was consistent with that in the training dataset, and there was good agreement between the predicted and observed incidence of PE. In the combined data from the training and validation datasets, good prediction for PE was achieved in screening by a combination of maternal factors, MAP, UtA-PI, PlGF, sFlt-1 and PSV ratio, with a DR, at a 10% SPR, of 85.0% (95% CI, 76.5-91.4%) for delivery with PE within 3 weeks and 65.7% (95% CI, 59.2-71.7%) for delivery with PE at any time after assessment. The performance of a biophysical test was superior to that of screening by low PlGF concentration or high sFlt-1/PlGF concentration ratio but not significantly different from the performance of a biochemical test combining maternal factors with PlGF and sFlt-1 for both PE within 3 weeks and PE at any time after assessment. CONCLUSION: Maternal ophthalmic artery PSV ratio at 35-37 weeks' gestation in combination with other biomarkers provides effective prediction of subsequent development of PE. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Pré-Eclâmpsia , Gravidez , Feminino , Humanos , Pré-Eclâmpsia/diagnóstico por imagem , Fator de Crescimento Placentário , Terceiro Trimestre da Gravidez , Artéria Oftálmica/diagnóstico por imagem , Biomarcadores , Artéria Uterina/diagnóstico por imagem , Fluxo Pulsátil , Receptor 1 de Fatores de Crescimento do Endotélio Vascular , Valor Preditivo dos Testes
20.
BJOG ; 131(2): 222-230, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37431533

RESUMO

OBJECTIVE: Investigate cost-effectiveness of first trimester pre-eclampsia screening using the Fetal Medicine Foundation (FMF) algorithm and targeted aspirin prophylaxis in comparison with standard care. DESIGN: Retrospective observational study. SETTING: London tertiary hospital. POPULATION: 5957 pregnancies screened for pre-eclampsia using the National Institute for Health and Care Excellence (NICE) method. METHODS: Differences in pregnancy outcomes between those who developed pre-eclampsia, term pre-eclampsia and preterm pre-eclampsia were compared by the Kruskal-Wallis and Chi-square tests. The FMF algorithm was applied retrospectively to the cohort. A decision analytic model was used to estimate costs and outcomes for pregnancies screened using NICE and those screened using the FMF algorithm. The decision point probabilities were calculated using the included cohort. MAIN OUTCOME MEASURES: Incremental healthcare costs and QALY gained per pregnancy screened. RESULTS: Of 5957 pregnancies, 12.8% and 15.9% were screen-positive for development of pre-eclampsia using the NICE and FMF methods, respectively. Of those who were screen-positive by NICE recommendations, aspirin was not prescribed in 25%. Across the three groups, namely, pregnancies without pre-eclampsia, term pre-eclampsia and preterm pre-eclampsia there was a statistically significant trend in rates of emergency caesarean (respectively 21%, 43% and 71.4%; P < 0.001), admission to neonatal intensive care unit (NICU) (5.9%, 9.4%, 41%; P < 0.001) and length of stay in NICU. The FMF algorithm was associated with seven fewer cases of preterm pre-eclampsia, cost saving of £9.06 and QALY gain of 0.00006/pregnancy screened. CONCLUSIONS: Using a conservative approach, application of the FMF algorithm achieved clinical benefit and an economic cost saving.


Assuntos
Aspirina , Pré-Eclâmpsia , Gravidez , Feminino , Recém-Nascido , Humanos , Aspirina/uso terapêutico , Primeiro Trimestre da Gravidez , Pré-Eclâmpsia/diagnóstico , Pré-Eclâmpsia/prevenção & controle , Pré-Eclâmpsia/tratamento farmacológico , Estudos de Coortes , Estudos Retrospectivos , Análise Custo-Benefício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...